The Pine Instrument Company Portable Gyratory Compactor AFG1 is the first compactor that allows the operator to take the machine to the material. The AGF1's smaller size, along with integral wheels and handles, makes this a truly mobile unit, perfect for field QC/QA work yet suitable for laboratory design. This compactor provides all the test data needed to meet current SUPERPAVE™ asphalt mix design requirements at the job site or in the lab. The AFG1 continues Pine's tradition of producing asphalt testers that are easy to use, loaded with features, and sturdy enough to provide years of reliable service in the demanding construction industry environment. One of the many features Pine has incorporated into the AFG1 is total electrical operation. Only 15 amps of current at 110 VAC are required to power the entire unit.
PINE PAVE SOFTWARE The AFG1 is supplied with user-friendly Pine-Pave Software. This PC based software package utilizes Microsoft Excel templates to assist the asphalt technician with data retrieval from the AFG1. AFG1 FEATURES
  • Integrated wheels and handles for true mobility.
  • Reduced size and weight.
  • Portable.
  • Completely electrical (110 VAC) operation.
  • Angle is continuously measured and displayed.
  • Easy-to-use controls.
  • Pine-Pave (PC-based) Mix Design software included.
  • Serial port for connection to external PC.
  • Parallel port for connection to external printer.
  • Rugged construction for low maintenance.
SPECIFICATIONS
Power Requirements: 110 VAC, 60 Hz, 1 PH, 15A
Size (approx.): 750mm [W] x 750mm [L] x 1300mm [H] (30" x 30" x 54")
Weight (approx.): 294kg (650 pounds)
Consolidation Pressure: 600 kPa
Angle of Gyration: 1.25 degrees
Speed of Gyration: 30rpm
No. of Gyrations: 0-999
Data acquisition: Specimen height recorded once per gyration to within 0.1 mm
Specimen Diameter 150mm
Max. Initial Height: 250mm
Max. Final Height 50mm
Modes of operation 1) Compact to number of gyrations
2) Compact to specified height
Unit of measure: SI Units
Calibration: ASTM E$ and AASHTO T67 load calibration at factory, accurate to within 1%