The Elcometer 207 series of precision ultrasonic thickness gauges are designed to provide accurate measurements on thin materials. Using the latest transducer designs - the single element delay tip transducer - the Elcometer 207 gauges will measure thin materials in "Echo-to-Echo Mode" and then automatically switch to "Interface Echo Mode" when measuring thicker materials and plastics. Furthermore, the Elcometer 207's Echo-to-Echo Mode offers the user the ability to measure the materials' thickness WITHOUT removing the paint or coating. All Elcometer 207's and 207DL gauges now have a new operating mode, the PLAS Mode. This mode has been specifically designed to provide accurate readings when measuring thin plastics.
  • Two calibration options - Speed of Sound, Calibration to a known Thickness.
  • Backlight display on both versions.
  • Data output available on both versions.
  • 1000 reading memory in up to 10 batches (Elcometer 207DL only)
  • ElcoMaster™ and EDTS+ Excel Link supplied free of charge with the Elcometer 207DL.

Specifications:

 

Maximum Measurement Range 0.15-25.4mm (0.006-1.00") steel
Velocity Range

1250 - 10000m/s (0.0492 - 0.3937 in/µs)

Accuracy ±0.002mm (±0.0001") - depends on material and conditions
Resolution ±0.002mm (±0.0001")
Units

millimetres and inches

Operating Temperature

-30 to 50°C (-20 to 120°F)

Keypad type

Sealed Membrane

Display

4½ Digit Liquid Crystal Display with Backlight

Transducer

Each unit is supplied with 15MHz, 6mm (1/4") microdot right angle transducer

Power

AA 1.5V Alkaline or 1.2V NiCad cell

Battery Life

200hrs Alkaline (120hrs NiCad)

Weight

295g (10oz)

Size

63.5 x 114.3 x 31.5mm (2.5 x 4.5 x 1.24")

Case Type

Extruded aluminium

 

Elcometer 207

Elcometer 207DL

Interface-to-Echo Mode

l

l

Echo-to-Echo Mode

l

l

PLAS* Mode

l

l

High Speed Scan Mode

l

l

Differential Mode

l

l

Alarm Mode

l

l

Data Output

l

l

Data-Logging

l

EDTS+ Excel link Software

¯

l

ElcoMaster™ Software

¯

l

Part Numbers

C207----1

C207DL----1

Accessories

Transducer Delay Line (for PLAS Mode)

T92016871
Ultrasonic Couplant (120ml / 4oz) T92015701

High Temperature Ultrasonic Couplant (60ml / 2oz)

T92015874
l Included  ¯ Optional
* To use the PLAS Mode, a special Graphite Delay Line is required which must be ordered separately, Part Number T92016871
ELCOMETER 207 ANS 207DL PRECISION ULTRASONIC TRANDUCER

Measurement Range

(in steel)

mm

(inches)

Material
Probe Type
Cast Iron
Plastic
Glass Fibre
Thin Glass Fibre
Steels
Glass
Thin Plastic
Aluminium
Potted
Straight Probe
Right Angle Probe
Microdot
High Temp. (340°C / 650°F)
Extra Resolution
Exxon Specification

0.15 - 25.4

(0.006 - 1.0)

l
l
l
l
l
l
l
l
Part Number
Frequency MHz (Colour Code)
Crystal Diameter mm(inches)

Wearface Diameter

mm(inches)

T92016526
15.0(green)
6.35(1/4)
7.42(5/16)