Supports the following standards: ASTM C511

The VaporPlus Curing Room System with Timer provides the ideal solution for maintaining concrete curing rooms within ASTM C511 specifications. The VaporPlus system utilizes air atomization technology to produce a fine vapor fog to create the optimal environment for storing and curing concrete testing samples, such as cylinders. It provides the ideal solution for maintaining the high humidity levels (up to 100%) required for curing rooms and ASTM C511.

The system is comprised of a simple timer control, a water filtration unit, which includes sediment removal and 100% KDF, anti-bacterial filter and a compressor unit, which includes an adjustable water regulator for added humidity control. The system also uses a stainless steel, air atomizing nozzle, which produces a fine vapor fog. This nozzle will not rust and is resistant to clogging. In addition, this system includes the TriOBreeze Sanitizing System. The TriOBreeze is an effortless way to clean your curing room, without use the of harsh chemicals or manual labor. The system’s generation of activated oxygen (O(O3)) is a relatively simple process using ordinary air. Oxygen (O2) and nitrogen (N(O2)) are the raw materials. As the air is drawn through the reaction chamber, energy is supplied, which splits some oxygen molecules into oxygen atoms. Some of these atoms then quickly react with oxygen molecules to form activated oxygen.

The VaporPlus system is designed to provide consistent humidity results for standard-sized rooms, such as a 12′ x 12′ x 8′, or 1728 cubic feet. However, this single-nozzle system has successfully met ASTM C511 humidity requirements in rooms as large as 5600 cubic ft. Humidity readings can be affected by high ceilings, L-shaped or other room configurations. For these rooms or as rooms get larger, additional nozzles can be added to maintain consistent humidity levels throughout the room. Other factors, which affect humidity levels include nozzle location, as well as the air turnover within the room including times when doors or windows are opened.

VaporPlus Curing Room Systems are now available in several, easy-to-install models allowing you to choose the one that fits your room, budget and needs. Each system comes with a water filtration unit, which includes sediment removal and 100% KDF, anti-bacterial filter and a compressor unit. The systems also includes a stainless steel, air atomizing nozzle, which produces a fine vapor fog. This nozzle will not rust and is resistant to clogging. Tubing is included, which is easily assembled using quick-connect connections.

The TriOBreeze is an effortless way to clean your curing room, without use the of harsh chemicals or manual labor. The system’s generation of activated oxygen (O3) is a relatively simple process using ordinary air. Oxygen (O2) and nitrogen (N2) are the raw materials. As the air is drawn through the reaction chamber, energy is supplied, which splits some oxygen molecules into oxygen atoms. Some of these atoms then quickly react with oxygen molecules to form activated oxygen.

  • O3 has a greater disinfection effectiveness against bacteria and viruses compared to chlorination
  • O3 kills pathogens on contact, converts to regular oxygen, and leaves no toxic residuals
  • O3 is effective against Listeria, Salmonella, Coli, Norovirus, Campylobacter and other pathogens

Monitor the VaporPlus System with M&L Testing Equipment‘s NEW Concrete Humidity Sensor System!
Based on M&L Testing Equipment‘s Concrete Maturity System, the Humidity Sensor System can be used to wirelessly monitor curing room humidity. This add-on product to the VaporPlus Curing Room System provides a wireless solution to collecting humidity data. Humidity can be accessed from anywhere without even visiting the curing room.

When the system is installed, it is activated by registering it with your website account using a sensor-specific ID number. Once this step is completed, the transmitter for each sensor will begin to receive data from the sensor and transmit that data to the receiver. The receiver then relays this information to your account on the web-based cloud platform. This information/data is available to you in real time, 24/7, 365 days a year by simply logging into your account, using your user name and password.

The Humidity Sensor System is sold separately as a kit, which includes (1) Receiver, (1) Transmitter/Sensor, and a website platform account. See: H‑2689.3F

Products

Part Number & Name
H-2741T
Vapor Plus Humidity System with Timer plus TriOBreeze Sanitizer 115V 60Hz
H-2741T.2F
Vapor Plus Humidity System with Timer plus TriOBreeze Sanitizer 220V 60Hz
H-2741T.5F
Vapor Plus Humidity System with Timer plus TriOBreeze Sanitizer 220V 50hz

Accessories

Part Number & Name
H-2689.3F
M&L Testing Equipment Humidity Sensor System

Literature

Manuals, Data Sheets & Safety Data Sheets
H-2741 VaporPlusCuringRoomSystem (Data Sheet PDF)

Standards

Standards
ASTM C511